The KOM300A is a ultra low power consumption Green industrial media convertor, its full load power consumption is as low as 2.2 watts. The KOM300A supports 1 100Base-FX fiber port and 2 10/100Base-T(X) copper ports. The KOM300A provides 9-36 VDC or 18-72VDC redundant power inputs, or 85-264VAC/77-300VDC single power input, supports DIN-Rail mounting or Panel mounting, and IP40 protection class.
Green Ethernet solution with ultra low power consumption design, its full load power consumption is as low as 2.2 watts
1 100Base-FX port and 2 10/100Base-T(X) RJ45 ports
Redundant power inputs with wide voltage range
IP40 protection class
CE, FCC,UL508, Class I Div 2 certificates
Product Specifications | |
Standard | IEEE 802.3i(10Base-T) IEEE 802.3u(100Base-TX and 100Base-FX) |
Switch Properties | MAC Table: 2K Packet Buffer: 1Mbit Packet Forwarding Rate: 0.8Mpps Switching Delay<5μs |
Interface | Fast Ethernet Ports: 100Base-FX, SM/MM port, FC/SC/ST connector 10/100Base-T(X) RJ45 port |
LED | Indicators in the front panel Power LED: PWR1, PWR2 Interface LED: Link/ACT, Speed (RJ45 Ports); Link/ACT(Fiber Ports) |
Power Requirements | Power Input: 100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) 24-48VDC(18-72VDC) 12-24VDC(9-36VDC) Power Terminal: 5-pin 5.08mm-spacing plug-in terminal block Power Consumption:<2.2w Overload Protection: Support Reverse Connection Protection: Support Redundancy Protection: Support |
Physical Characteristics | Housing: Metal Heat Dissipation Mode: Natural cooling, without fans Protection Class: IP40 Dimensions: 30mm×115mm×91.5mm(W×H×D) Weight: 0.46kg Mounting: DIN-Rail or Panel mounting |
Environmental Limits | Operating Temperature: -40°C to +85°C Storage Temperature: -40°C to +85°C Ambient Relative Humidity: 5-95% (non-condensing) |
Quality Assurance | MTBF: 462,741 hrs Warranty: 5 years |
Approvals | CE(EMC), FCC: Models with HV:100-240VAC,50/60Hz;110-220VDC and L2:24-48VDC. UL508, Class I Div 2: Models with L2:24-48VDC. |
Industry Standard | EMI: FCC CFR47 Part 15,EN55032/CISPR22,Class A EMS: IEC61000-4-2(ESD) ±8kV(contact),±15kV(air) IEC61000-4-3(RS) 10V/m(80MHz-2GHz) IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV IEC61000-4-5(Surge) Power Port:±2kV/DM,±4kV/CM;Data Port:±2kV IEC61000-4-6(CS) 3V(10kHz-150kHz);10V(150kHz-80MHz) Mechanical standards: IEC60068-2-6 (Vibration), IEC60068-2-27 (Shock), IEC60068-2-32 (Free Fall) |
KOM300A-Ports-Connector-PS1-PS2 | |
Ports | |
1S2T | 1 × 100Base-FX single mode port, 2 × 10/100Base-T(X) RJ45 ports |
1M2T | 1 × 100Base-FX multi mode port, 2 × 10/100Base-T(X) RJ45 ports |
Connector | 100M fiber port specifications |
SC05 | SC connector, multi-mode, 1310nm, 5km |
ST05 | ST connector, multi-mode, 1310nm, 5km |
FC05 | FC connector, multi-mode, 1310nm, 5km |
SC40 | SC connector, single-mode, 1310nm, 40km |
ST40 | ST connector, single-mode, 1310nm, 40km |
FC40 | FC connector, single-mode, 1310nm, 40km |
SC60 | SC connector, single-mode, 1310nm, 60km |
SC80 | SC connector, single-mode, 1550nm, 80km |
PS | |
HV | 100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC), single power input |
L2-L2 | 24-48VDC(18-72VDC), redundant power inputs |
L5-L5 | 12-24VDC( 9-36VDC), redundant power inputs |
Accessories | |
DT-BGAZ-01 | Panel for panel mounting |
DT-FCZ-RJ45-01 | Dustproof cover for RJ45 port |